Pra-Oil Leakage detection test
Release time:2018-11-23

The main aim has been to demonstrate the feasibility relative easy integration of this kind of innovative leakage detection system based on distributed fibre optic technology

The area available for the test has allowed the use of approx. 200m polyethylene pipeline buried under 1m of argillaceous soil. The leakage simulation was achieved by hot water injection in the soil through several valves at different positions along the pipe.

 

Aim of monitoring:

The main aim has been to demonstrate the feasibility relative easy integration of this kind of innovative leakage detection system based on distributed fibre optic technology


 

Main results:

The Smartec sensing cable was able to detect any simulated leakage, by localizing every single temperature variation within different border conditions.

INSTALLATION PERIOD TYPE OF SENSORS NUMBER OF SENSORS
2007 DiTeSt / DiTemp 2

Related Papers:

Pipeline Leakage Detection and Localization Using Distributed Fiber Optic Sensing, D. Inaudi, B. Glisic, A. Figini, R. Walder, Rio Pipeline Conference 2007, Rio de Janeiro, Brazil, October 2-4 – 2007
Detection And Localization of Micro-Leakages Using Distributed Fiber Optic Sensing, Daniele Inaudi, Riccardo Belli, Roberto Walder, 7th International Pipeline Conference, IPC2008, 29th September – 3rd October 2008 , Calgary, Alberta, Canada – 2008

The recommended scheme
Return
WeChat
Micro-blog
Total Solution Provider for Advanced Civil Engineering Testing Instruments
  • 400-700-9998
  • Service Time : Monday to Sunday, 9:00-18:00
  • E-mail : marketing@epc.com.hk
Copyright © 2008~2015 Earth Products China Ltd. all rights reserved. 粤ICP备12064742号 Domestic headquarters address:West Tower 2301, Fortune Plaza, No. 116, sports east road, Tianhe District, Guangzhou
Hong Kong Headquarter Address:12/F, Asia Trade Centre, 79 Lei Muk Road, Kwai Chung, Hong Kong
Home
Products
Solutions
About Us