Proceq - Ultrasonic, TOFD and phased array flaw detector and thickness gauge
Concrete Thickness Testing
    Model: Flaw Detectors (100UT, 100TOFD, 100PA 16:16, 100PA 16:64, Zonotip)
    Country of Origiin: USA
    Use: Meets EN 12668-1, ISO 18563-1, ГОСТ 55724, ГОСТ 14782.
  • consult
Details Solution Applications Downloads Order
Description

The Proceq Flaw Detector 100 has a large display to show the A-scans from the two onboard channels. The use is simple and efficient due to wizards and an active help file. 3D scan plans assist in creating inspection procedures and analyzing the results.

The upgrade to Proceq Flaw Detector 100 TOFD enables the TOFD application to deliver the highest performance. Two channels make it possible to inspect thick parts in a single pass. High frequency probes can be used to get accurate defect sizes.

The upgrade to Proceq Flaw Detector 100 PA 16:16 will bring a broad spectrum of applications that can be setup, performed and analyzed using the inbuilt wizards and user guides. For users wishing to learn about the phased array capabilities, or to show a sectoral scan. 

The upgrade to Proceq Flaw Detector 100 PA 16:64 allows even more flexibility in your setup. The additional multiplexing is beneficial for performing L-scans in corrosion mapping and when testing the integrity of large composite panels

The Zonotip is for thickness testing of a wide range of materials. Its high-contrast color display ensures visual control of the inspection process. The Zonotip+ includes a smaller single-element transducer which is suitable for measuring in areas where access is limited. 

Your Benefits
Simple code to upgrade anytime to TOFD and Phased Array (PA)
 

Simple code to upgrade anytime to TOFD and Phased Array (PA)

Bandwidth down to 200 kHz to test on attenuative materials, plus 2 axis encoding to record data
 

Bandwidth down to 200 kHz to test on attenuative materials, plus 2 axis encoding to record data

Improved traceability with automatic reporting
 

Improved traceability with automatic reporting

Only pay for the options you need
 

Only pay for the options you need

Advanced features such as lateral wave removal and lateral wave straightening
 

Advanced features such as lateral wave removal and lateral wave straightening

Perform two-channel TOFD inspections simultaneously
 

Perform two-channel TOFD inspections simultaneously

High level of performance for conventional portable flaw detection with the power of phased array
 

High level of performance for conventional portable flaw detection with the power of phased array

A, B, C, True Top and End scans imaging capabilities cover many applications
 

A, B, C, True Top and End scans imaging capabilities cover many applications

The 3D scan plan helps to visualize the phased array beam coverage in the component
 

The 3D scan plan helps to visualize the phased array beam coverage in the component

Compatible with any 64 element linear phased array probe
 

Compatible with any 64 element linear phased array probe

Simple 30 second configuration
 

Simple 30 second configuration

C scans can be displayed in amplitude or depth.  With merged C scans, data is displayed for all inspection passes in the same view
 

C scans can be displayed in amplitude or depth. With merged C scans, data is displayed for all inspection passes in the same view

Easy to setup and use
 

Easy to setup and use

The A scan mode allows a more in-depth analysis of the reading (Zonotip+ only)
 

The A scan mode allows a more in-depth analysis of the reading (Zonotip+ only)

Rugged housing for difficult weather conditions (frost- and heat-proof)
 

Rugged housing for difficult weather conditions (frost- and heat-proof)

Configuration

2 UT Channels

2 UT Channels

16:16 Channels

16:64 Channels

1 UT Channel

Transducer Socket

Lemo 1 and BNC

Lemo 1 and BNC

UT/TOFD: Lemo 1 and BNC PA: I-PEX

UT/TOFD: Lemo 1 and BNC PA: I-PEX

Lemo 00

Pulse Voltage

-100 to -450 V (in steps of 10 V)

-100 to -450 V (in steps of 10 V)

UT/TOFD: -100 to -450 V (in steps of 10 V) PA: -25 to -75 V (in steps of 5 V)

UT/TOFD: -100 to -450 V (in steps of 10 V) PA: -25 to -75 V (in steps of 5 V)

 
PRF

1 to 1500 Hz

1 to 1500 Hz

UT/TOFD: 1 to 1500 Hz PA: 1 to 5000 Hz

UT/TOFD: 1 to 1500 Hz PA: 1 to 5000 Hz

 
Gain Range

100 dB (0.1 dB steps)

100 dB (0.1 dB steps)

UT/TOFD: 100 dB (0.1 dB steps) PA: 76 dB (0.1 dB steps)

UT/TOFD: 100 dB (0.1 dB steps) PA: 76 dB (0.1 dB steps)

80 dB (1 dB steps)

Bandwidth

200 kHz to 22 MHz

200 kHz to 22 MHz

UT/TOFD: 200 kHz to 22 MHz PA: 200 kHz to 14 MHz

UT/TOFD: 200 kHz to 22 MHz PA: 200 kHz to 14 MHz

 

Solution
Applications
Downloads
Order
Related Recommendations
WeChat
Micro-blog
Total Solution Provider for Advanced Civil Engineering Testing Instruments
  • 400-700-9998
  • Service Time : Monday to Sunday, 9:00-18:00
  • E-mail : marketing@epc.com.hk
Copyright © 2008~2015 Earth Products China Ltd. all rights reserved. 粤ICP备12064742号 Domestic headquarters address:West Tower 2301, Fortune Plaza, No. 116, sports east road, Tianhe District, Guangzhou
Hong Kong Headquarter Address:12/F, Asia Trade Centre, 79 Lei Muk Road, Kwai Chung, Hong Kong
Home
Products
Solutions
About Us